
- SCAD DOWNLOAD TOON BOOM HARMONY INSTALL
- SCAD DOWNLOAD TOON BOOM HARMONY UPDATE
- SCAD DOWNLOAD TOON BOOM HARMONY LICENSE
In the InstallShield Welcome window, click Next to continue with the installation. This will only affect the installer and will not change the language of the actual software. Select the language in which you want the installer to execute and click OK. Installing Toon Boom Harmonyĭownload the build of Harmony that you are going to install.ĭouble-click on the Harmony InstallShield executable.

But this will require extra caution, if you are at all unsure contact your system administrator or Toon Boom Animation Support. You can, however, back up current /usa_db and /usadata by renaming them (this procedure can only be used when installing on the same server). This will prevent you from losing any data during the upgrading process.

conf file that is required to be used later.įor the server upgrading process, please backup the database by exporting the whole database. nf from any machine (including the server) that is doing a batch vectorization.Īny other. nf if this workstation is to be configured as a scanning station. įor V7.3, go to \Program Files (x86)\Toon Boom Animation\Harmony\etc.įor V7.2 and earlier, go to the \usa\etc folder.īack up any necessary configuration files: 1.įor V7.8, go to \Program Files (x86)\Toon Boom Animation\Harmony 7.8\etc. You can also back up the license.dat during this procedure. You also need to back up any necessary configuration files from the machine in case you want to reuse them. In the System Variables panel, select LM_LICENSE_FILE if it is listed, and then click Delete button to delete LM_LICENSE_FILE.ĭelete any of the following variables if they appear in the System or User variables lists: TOONBOOM_LICENSE_FILE, USADB, USADIR or USAROOT. In the Advanced tab, click on the Environment Variables button. To complete the installation, you need to remove some environment variables set by the previous installation.Ĭlick the Start menu and select Control Panel.ĭouble-click on System and select the Advanced system settings link in the left panel.
SCAD DOWNLOAD TOON BOOM HARMONY LICENSE
In the Config Services tab, click the Remove Service button to remove the license service. Next, in the Start/Stop/Reread tab, select the license server in the Remote Server List. If you are upgrading from version 7.8 click the Start menu, and select All Programs > Toon Boom Harmony 7.8 > License Tools > Flexlm Tools. If you are upgrading from version 7.3 click the Start menu, and select All Programs > Toon Boom Animation > Harmony > Tools > Flexlm Tools. Turn off all of the client machines and the render farm.įirst, click the Start menu, and select All Programs > Harmony > Configuration Tools > FLEXlm - lmtools. Do this for every Toon Boom Harmony related process running on the machine.ĭuring this process, you will be able to stop the tbdbserver on the server and tbprocess on workstations that are set as a batch render. Select a process from the Process Starter drop-list and click Stop. Upgrading from V7.8, V9.2 or a previous V10 version: ‣Ĭlick the Start menu, select All Programs > Toon Boom Harmony > Tools > Control Panel. Upgrading from a previous version of V7.3: ‣Ĭlick the Start menu, select All Programs > Toon Boom Animation > Toon Boom Harmony > Tools > Harmony Control Panel. The queues should either be empty or the status of all jobs should be "Completed".Ĭlick the Start menu, select All Programs > Toon Boom Harmony (or Opus) > Configuration Tools > usa_cfg. In the Control Center module, use the Queue menu to open the Vectorize and Render Queue for all environments. You can check the status of the Vectorize and Render queues from the Control Center module. Make sure that all batch rendering or vectorizing is complete or that the queues are empty. Make sure that no one is running Toon Boom Harmony.Īll Toon Boom Harmony modules must be closed on the server and on all of the clients. To stop all services affecting Toon Boom Harmony: 1.

Uninstalling the Previous Version of Toon Boom Harmony or Opus Removing Harmony Related Environment Variablesīacking up any Necessary Configuration Files:
SCAD DOWNLOAD TOON BOOM HARMONY UPDATE
During the upgrade, no users can run any of the Toon Boom Harmony modules and all rendering jobs must be stopped and complete.īefore you can update a previous installation of Toon Boom Harmony, you must stop all services, including: If you are performing an upgrade, you should pick a time when Toon Boom Harmony production is slow or stopped.

If you are not upgrading from a previous installation of Toon Boom Harmony, go directly to Installing Toon Boom Harmony.
SCAD DOWNLOAD TOON BOOM HARMONY INSTALL
Now that you have verified your minimum requirements, and configured your hardware and software, you are ready to install Toon Boom Harmony.
